A STUDY OF ANTI-PROTRUDING PROPERTIES OF DURA AND ITS SUBSTITUFES
ding Zurong(Department of Engineering Mechanics, Shanghai Jiaotong University, Shanghai 200030)
song Donglei,Zhou Liangfu(Department of Neurosurgery, Shanghai Huashan Hospital, Shanghai 200040)
Abstract:The study of anti-protruding properties of dura and its substitutes is important to reconstnlction of skull defecfs. The parameters of anti-protruding properties of dura and its substitutes are introduced on the basis of constant creep solution of the dural deflection under the constant intracranial pressure. Dura and its Substitutes are arranged in order to the parameters: fresh human dura is the best anti-protruding material, lyophilized human dura is the best substitute, and artificial membrane of bovine cardiac valve, silicone rubber and terylene are unsuitable for use as anti-protruding material. The measurements showed that dura is isotropic approximately, which temporalis myofascia and pericranium are anisotropic.
Keywords:Dural Reconstruction, lyophilized dura, dura substitutes, anti-protruding properties.参考文献:
[1]吴彦桥,任光.颅底肿瘤术后缺损的重建和修复材料研究进展.中国耳鼻咽喉颅底外科杂志1995;1:56.
[2]丁祖荣,宋冬雷,李士其等.硬脑膜及其替代物的蠕变特性.上海交通大学学报1998;32:93.
[3]Galford J E,Mcelhaney JH.A viscoelastic study of scalp brain and dura.J Biomechanics 1970;3:211.
[4]朱兴华,施德广,董心等.人体硬脑膜、大脑镰和小脑镰的力学试验研究.吉林工业大学学报1988;9:46.
[5]丁祖荣,宋冬雷,周良辅等.硬脑膜稳态蠕变膨出研究.上海交通大学学报2000;34.
[6]杨立,于彦铮,余建伟.生物瓣膜性能的研究——硬脑膜的形态结构及脉动流测试.人工心膜瓣膜的脉动流测试及生物材料的研究报告1991;87~95.
[7]周晓平,赵盂尧,岳志健等.冻干人体硬脑膜移植的实验研究和临床应用.中华实验外科杂志1992;9:4.