THE MECHANICAL tESTING MODEL OF A BIODEGRADABLE SCREW IN VITRO DEGRADATION
Hung wen Wei ,Ruey yug tsay ,Chengkung Cheng(Institute of Biomedical Engineering, National Yang Ming University, Taipei, taiwan)
Abstract:The strength and decay rate of biodegradable fixation device can be monitored and improved by means of in vitro degradation tests. However, from literature review, it is found that the testing procedure and controlled degradation environment applied in various vitro tests are not the same. Therefore, the purpose of this study is to establish an in vitro degradation sysytem by monitoring the degradation system of mechanical strength of a biodegradable bone screw. Conditions set for in vitro degradation and mechanical tests refer to aSTM F1635 and relevant papers. The sample screws, offered by Industrial technology Research Institute, are made of two different materials, ie, Poly-L-lactic(PLLA) acid and the copolymer of Poly-L-lactide and Poly-glycolide(PLGA).They were put in several containers and immersed in isotonic PBS(pH=7.4±0.2, 0.15M NaC1). The temperature of buffer solution was maintained at 37±2℃ by a shake bath. Both of the shear and three points bending tests were carried out to monitor the decay of the mechanical strength of the screws. The resulting mechanical strength reported here in is an average of 5 samples. The present results indicate that the strength of PLLA screws decreased significantly among week 6 to week 7 and PLGA screws lost almost all its strenght in about 4 week. The in vitro degradation system developed here in could be applied to help evaluation the performance of a biodegradable screw.
Keywords:Biodegradable screw, in vitro, Mechanical Test
作者简介:蔡瑞莹通讯作者参考文献:
[1]“Standsrd Test Method for in vitro Degradation testing of poly(L-lactic Acid)resin and fabricated from for surgical implants” aSTM F1635~95, 1998.
[2]Mainil-Varlet, P., Curtis, R., and Gogolewski, S., Effect of in vivo and in vitro degradation on molecular and mechanical properties of various low-molecular-weight poly-lactides, Journal of Biomedical Materials Research.36(3): 360~80, 1997 Sep 5.
[3]Suuronen, R. et al., Strength retention of self-reinforced poly-L-lactide screws and plates: an in vivo and in vitro study, Journal of Materials Science: materials in Medicine, 3; 426~31, 1992.
[4]Tormala, P., Vasenius, J., Vainionpa, S., Laiho, J., Pohjonen, T., and rokkanen, P., Ultra-high-strenght absorbable self-reinforce polyglycolide (SR-PGA) composite rods for internal fixation of bone fractures: in vitro and in vivo study., Journal of Biomedical Materials Research. 25(1):1~22, 1991 Jan.
[5]Matsusue, Y., Yamamuro, T., Oka, M., Shikinami, Y., Hyon, SH., and Ikada, y., In vitro and in vivo studies on bioabsorbable ultra-high-strength poly(L-lactide)rods. Journal of Biomedical Materials Research. 26(12): 1553~67,1992 Dec.